Specialist compressor ac & chiller

Danfoss SC21G Compressor
High-efficiency refrigeration compressor for R134a applications
Rp123.00
Out of stock
Upgrade your refrigeration system with the high-performance Danfoss SC21G compressor, engineered specifically for industrial applications using R134a refrigerant. Featuring versatile voltage compatibility (220-240V, 50/60Hz), this robust compressor ensures reliable and efficient cooling across a wide range of environments. Manufactured by Secop in China, it adheres to rigorous international safety and efficiency standards for absolute peace of mind. Its compact black housing is designed for space-saving installation, while the durable build promises long-term, dependable operation. Perfect for commercial and industrial cooling solutions—choose the SC21G for unmatched reliability and performance.
Compressor Type | Reciprocating |
|---|---|
Horse Power | 3/4 PK |
Refrigerant | R134A |
Phase | 1 Phase |
Voltage | 220~240 V |
Frequency | 50 Hz |
Nett Weight | 13 Kg |
o Apa penyebab Compressor lama Tidak dapat Berfungsi/Rusak?
o Voltase listrik yang tidak stabil
o Ada kerusakan pada system Electrical
o Ada penyumbatan didalam system
o Adanya kebocoran sehingga oli berkurang didalam Compressor
o Faktor penyusutan /lamanya pemakaian
o Apakah Voltase listrik sudah stabil ?
o Pastikan system lainnya dalam rangkaian system Baru/berfungsi dengan Baik sehingga tidak terjadi penyumbatan;
o Filter Dryer {Harus diganti}
o Expantion Valve {Direkomendasikan untuk diganti}
o Oil separator dan accumulator
o Lainnya yang tidak disebutkan diatas
o Apakah saluran pipa sudah dibersihkan dengan R11 dan didorong bersih oleh N2 ?
o Apakah system menggunakan oil separator dan accumulator{Direkomendasikan untuk diganti}, Pada saat Flushing R11 Jangan melewati oil separator dan accumulator.
o Pastikan spesifikasi compressor yang dibutuhkan system telah sesuai.
o Umumnya Compressor Tidak bergaransi, maka telitilah dalam Pemasangannya.
o Cek terminal R-S-T Compressor dengan multitester.
o Cek Kecukupan Oli Pelumas pada compressor.
o Sebelum pengelasan Compressor Harap di tes terlebih dahulu,Pastikan rangkaian posisi R-S-T atau T1-T2-T3 atau L1-L2-L3 dari sumber listrik ke panel PCB,kontaktor,kemudian ke terminal compressor telah Benar dan pastikan Discharge dan Suction telah berfungsi dengan Baik.{Khusus compressor tertentu apabila pemasangan Rangkaian Listrik terbalik akan menyebabkan compressor tersebut berdengung/Putaran terbalik dan berakibat Rusak seketika}
o Pengelasan Compressor dibutuhkan keahlian pengelasan yang Cepat dan Rapi, Apabila pengelasan yang terlalu lama akan menyebabkan terminal didalam Compressor meleleh dan Kontak Body.
o Pastikan semua Stop kran/Hand Valve sudah dalam posisi terbuka.
o Vaccum menggunakan mesin vaccum sampai -30 Psig.
o Pengisian gas pendingin direkomendasikan produksi Dupont, Isi secara perlahan sampai mencapai Batas Low pressure yang ditentukan, barulah mesin di jalankan.
o Kontrol Tekanan Standard tergantung jenis Gas pendingin yang direkomendasikan
o Kontrol Tegangan Ampere Standard yang direkomendasikan.
o Pastikan tidak ada kebocoran gas pendingin pada system.
o Pastikan Condensor dan Evaporator telah dibersihkan untuk menghasilkan dingin maksimal pada evaporator.
o Dalam pemasangan Compressor selalu ada resiko Gagal, maka berdoalah terlebih dahulu.